| Specifications |
| Input voltage | 8-30 VDC nominal |
| Input current | 4.3 A at 9 V input | 1.3 A at 30 V input |
| Total output power | 37W maximum with forced external cooling |
| Efficiency | > 90% overall input voltage range |
| Output voltages and currents | +5 VDC at 5 A maximum rating |
| +12 VDC at 0.5 A maximum rating |
| -12 VDC at 0.5 A maximum rating |
| Output accuracy | ±0.24 V for +12 V output |
| | ±0.24 V for - 12 V output |
| | ±0.1 V for 5 V output |
| Temperature range | -25°C to 50°C operating range |
| Output ripple | Pk - Pk 100 mV on 5 V | 100 mV on 12 V |
| Line regulation (full input voltage rating) | ±0.12 V for +12 V output |
| ±0.12 V for -12 V output |
| ±0.05 V for 5 V output |
| Load regulation (full load swing | ±0.12 V for + 12 V output |
| | ±0.12 V for -12 V output |
| | ±0.025 V for +5 V output |
| Protection | Reverse input polarity: Unit will restart when correct input polarity is established. |
| Short circuit | Unit will turn off when a short circuit is detected. Power cycling the unit forces the power supply to start after a short circuit event. |
| Load damp protection | Unit is protected against load dump transients |
| | |